Automatic terminal machine common fault detection method!

Source: Time:2020-11-25 11:53:03 views:

There are many reasons for the different openings. Common ones are that the wire feed wheel is pressed too tightly or loosely; At this time, you only need to adjust the gap between the two wheels with the fine-tuning parts of the wire roller so that the wire is not flattened and too loose and slippery.
1, peeling opening length is different: There are many reasons for the different openings. Common ones are that the wire feed wheel is pressed too tightly or loosely; At this time, you only need to adjust the gap between the two wheels with the fine-tuning parts of the wire roller so that the wire is not flattened and too loose and slippery. If it is because the cutting knife cuts too shallow or too deep; Then we will adjust the blade to a proper position by adjusting the depth of the cutter, so as not to hurt the copper wire and the rubber can fall off smoothly. If you still have different openings, replace the new cutting blade directly. 2. Uneven copper wire exposed at the pressure terminal: Check whether the gun-type swing arm conduit is attached to the wire; Whether the knife edge of the terminal machine is relatively straight with the swing arm conduit; Whether the auxiliary press block of terminal machine is loose; Check whether the distance between the terminal machine and the automaton has changed. 3. The terminal machine cannot be started or stopped during operation: If it can't be started or stopped during operation, firstly, check whether there is current input and 6KG air pressure, and whether there is wireless material or a running part stuck; And check whether the terminal machine has signal connection or power connection, so that the terminal machine is not pressed. 4. The cutting length of the electronic wire of the terminal machine is inconsistent: May be tangent knife edge wear or knife edge; It's simple to replace a new knife when encountering such a problem. It may also be because the wire feed wheel is pressed too tightly or too loosely; At this time, we can adjust the gap between the two wheels with the fine-tuning parts of the wire roller so that the wire is not flattened and too loose to slip.

Previous:Function of step servo motor in automatic terminal machine

Next:Already the last article

Return